Documentation for CU2608 8-Port Ethernet switch with IP67 protection class Version: 1.0.0 Date: 2014-07-23

Página 2

Product overview 6 CU2608 Technical Data Technical Data CU2608-0000 Bus system all Ethernet based protocols (IEEE 802.3) Store-and-Forward switc

Página 3 - Table of contents

Mounting and cabling CU2608 7 3. Mounting and cabling Dimensions All dimensions are given in millimeters. Housing properties EtherCAT Box lean

Página 4

Mounting and cabling 8 CU2608 Fixing Note or pointer Note While mounting the modules, protect all connectors, especially the IP-Link, against con

Página 5 - 1. Foreword

Mounting and cabling CU2608 9 Nut torque for connectors M8 connectors It is recommended to pull the M8 connectors tight with a nut torque of 0.4

Página 6 - Description of symbols

Mounting and cabling 10 CU2608 Ethernet cables For connecting Ethernet devices only shielded Ethernet cables that meet the requirements of at leas

Página 7 - Documentation issue status

Mounting and cabling CU2608 11 ZK1090-6191-0xxx: M12 plug - RJ45 plug, ready-assembled ZK1090-6191- 0005 0010 0020 0025 0050 0100 Length 0.

Página 8 - 2. Product overview

Mounting and cabling 12 CU2608 Power cables Ordering data Order designation Power lead Screw-in connector Contacts Cross- section Length ZK2020

Página 9 - CU2608 5

Mounting and cabling CU2608 13 Power cable conductor losses The ZK2020-xxxx-yyyy power cables should not exceed the total length of 15 m at 4 A (

Página 10 - Technical Data

Mounting and cabling 14 CU2608 LED Displays Ethernet For each of the eight channels 1 LEDs show the current status. LED display per channel LED

Página 11 - 3. Mounting and cabling

Mounting and cabling CU2608 15 Power Supply Present supply voltage (24 VDC) is shown by the green power LED. LED Display Meaning off The powe

Página 13 - Torque socket wrenches

Appendix 16 CU2608 4. Appendix General operating conditions Protection degrees (IP-Code) The standard IEC 60529 (DIN EN 60529) defines the degree

Página 14 - Sold by meter

Appendix CU2608 17 Chemical Resistance The Resistance relates to the Housing of the Fieldbus Box and the used metal parts. Character Resistance S

Página 15 - CU2608 11

Appendix 18 CU2608 Support and Service Beckhoff and their partners around the world offer comprehensive support and service, making available fast

Página 16 - Power cables

Table of contents CU2608 Table of contents CU2608 - Ethernet Switch (IP67) 1. Foreword 1 Notes on the documentation 1 Safety instructions Fe

Página 18 - Ethernet

Foreword CU2608 1 1. Foreword Notes on the documentation This description is only intended for the use of trained specialists in control and autom

Página 19 - Power Supply

Foreword 2 CU2608 Safety instructions Safety rules Consider the following safety instructions and descriptions! Product specific safety instructio

Página 20 - 4. Appendix

Foreword CU2608 3 Documentation issue status Version Comment 1.0.0 first release (technical data updated) 0.5.0 preliminary

Página 21 - EtherCAT Box - Accessories

Product overview 4 CU2608 2. Product overview Introduction 8-port Ethernet Switch with IP67 protection class The CU2608 Ethernet Switch offers ei

Página 22 - Beckhoff Headquarters

Product overview CU2608 5 Basic Function Principles Store and Forward The switch operates according to the store-and-forward principle. Frames tha