Beckhoff C1300 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Beckhoff C1300. BECKHOFF C1300 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 44
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
C1300 VME to II/O Interface Unit Beckhoff II/O-System
Date : 18.12.95 Version : 2.01 Page 1 of 44
VME to II/O Interface Unit
Technical Documentation
Eiserstraße 5 phone: +49(0)5246/963-0
33415 Verl fax: +49(0)5246/963-149
Vista de página 0
1 2 3 4 5 6 ... 43 44

Resumo do Conteúdo

Página 1 - VME to II/O Interface Unit

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 1 of 44VME to II/O Interface UnitTechnical DocumentationEise

Página 2 - Table of contents

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 10 of 44 Version : 2.01 Date : 18.12.952. Function Description HardwareC1300The central modu

Página 3

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 11 of 443. Function Description Software3.1. About the Softw

Página 4

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 12 of 44 Version : 2.01 Date : 18.12.95

Página 5 - 1. System Description

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 13 of 443.2. Description of the Handshake ChannelsCommunicat

Página 6

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 14 of 44 Version : 2.01 Date : 18.12.95Address Address Bits Contents(hex)76543210C00 1 x 0 0

Página 7

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 15 of 44Handshake sequence : :0C00 80h Data Valid VME-Master

Página 8

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 16 of 44 Version : 2.01 Date : 18.12.95Functions provided are :No.(hex)Function01 LWL-RESET0

Página 9

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 17 of 443.3. Test and Analysis FunctionsFunction 01h : FO-RE

Página 10

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 18 of 44 Version : 2.01 Date : 18.12.95Funktion 02h : Code word requestAfter each reset the

Página 11 - 3.1. About the Software

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 19 of 44Function 03h : Softwareversion requestFunction 03h i

Página 12

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 2 of 44 Version : 2.01 Date : 18.12.95Table of contents1. System Description...

Página 13

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 20 of 44 Version : 2.01 Date : 18.12.95Function 05h : Absorbtion testThe light absorbtion of

Página 14

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 21 of 44Funktion 06h :Count ModulesBy means of this function

Página 15

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 22 of 44 Version : 2.01 Date : 18.12.95Funktion 07h : Address testThis function is used to p

Página 16

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 23 of 44Funktion 08h : continuous transmissionThis function

Página 17

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 24 of 44 Version : 2.01 Date : 18.12.95Funktion 09h : Software-RESETThis Function is used to

Página 18

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 25 of 44Funktion 0ah : Fraction TestThis function can be use

Página 19

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 26 of 44 Version : 2.01 Date : 18.12.95Funktion 0ffh: Wrong Functionin case there is a funct

Página 20

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 27 of 443.4. ConfigurationThere are four functions to descri

Página 21 - 04 06 01 00

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 28 of 44 Version : 2.01 Date : 18.12.95Funktion 0ch : reinitialize communication managementT

Página 22

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 29 of 44Example:3.4.1. CDL-CommunicationA CDL is created for

Página 23 - constant transmission can be

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 3 of 44

Página 24

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 30 of 44 Version : 2.01 Date : 18.12.95Example of a descriptor:Telegram to II/O-module 1 :

Página 25 - 04 0a 01 ff

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 31 of 44Funktion 10h: Transmit CDL-ConfigurationThe CDLs des

Página 26 - ( reserved )

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 32 of 44 Version : 2.01 Date : 18.12.953.4.2. Free programmable CommunicationThis way of com

Página 27

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 33 of 44Funktion 0bh: Initialization of free programmable co

Página 28

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 34 of 44 Version : 2.01 Date : 18.12.95Example:Initialization of communication 3 as a free c

Página 29

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 35 of 44Function 12h: Free running communicationFunction 12

Página 30

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 36 of 44 Version : 2.01 Date : 18.12.953.4.3. Initialisation of "Fast Fiber Optic - Int

Página 31

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 37 of 44Example:Channel Length Function Argument0Argument1Ar

Página 32

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 38 of 44 Version : 2.01 Date : 18.12.953.5. Signal state control functionsThe General Contro

Página 33

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 39 of 44call mask:P8 P1 <- - priorityready mask:P8 P1with

Página 34

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 4 of 44 Version : 2.01 Date : 18.12.95...

Página 35 - 03 12 00 00 says: ok

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 40 of 44 Version : 2.01 Date : 18.12.95IRQ Data out:----IO3IO2IO1IO0If the VME system modifi

Página 36

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 41 of 444. Technical Data Port prozessorSiemens SAB 80C166-S

Página 37

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 42 of 44 Version : 2.01 Date : 18.12.955. Installation5.1. ConfigurationThe central module C

Página 38

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 43 of 44

Página 39

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 44 of 44 Version : 2.01 Date : 18.12.955.3. Installation on the VME Card Cage1. Switch off t

Página 40 - - - - - II3 II2 II1 II0

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 5 of 441. System Description1.1 The Beckhoff II/O Systemthe

Página 41 - 4. Technical Data

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 6 of 44 Version : 2.01 Date : 18.12.95The connection of the II/O system to the host system

Página 42 - 5. Installation

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 7 of 44A telegram consists of a frame and the contents. pic

Página 43

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemPage 8 of 44 Version : 2.01 Date : 18.12.95The contents of the telegram is mainly organized for e

Página 44

C1300 VME to II/O Interface Unit Beckhoff II/O-SystemDate : 18.12.95 Version : 2.01 Page 9 of 44The Beckhoff II/O fieldbus consists of a physical rin

Comentários a estes Manuais

Sem comentários