Chapter: Connectors SATA, PATA, FDD, Memory
page 26 Beckhoff New Automation Technology CB1052
3.3.3 Floppy interface
A floppy drive can be attached in one of two alternative ways: One is a standard 2x17-pin connector (FCI
75869-306LF) for ribbon cables, the other is a 26-pin connector (JST 26FMZ-BT) for Flat Flex cables
(FFC).
CAUTION
The two connectors can only be used one at a time.
Pinout FFC connector (FDD):
Pin Name Description
1 VCC 5 volt supply
2 IDX# index
3 VCC 5 volt supply
4 DR0# drive sel 0
5 VCC 5 volt supply
6 DC# disk change
7 N/C reserved
8 N/C reserved
9 N/C reserved
10 MT0# motor enable 0
11 N/C reserved
12 DIR# direction
13 N/C reserved
14 STP# step
15 GND ground
16 WD# write data
17 GND ground
18 WE# write enable
19 GND ground
20 TR0# track 0
21 GND ground
22 WPRT# write protect
23 GND ground
24 RDATA# read data
Comentários a estes Manuais