Beckhoff AX2000 CANopen communication profile Manual do Utilizador Página 68

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 137
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 67
Sub-index
09
h
Brief description
resolution / numerator of the gearing ratio
Unit
μm
Access
rw
PDO mapping
not possible
Data type
UNSIGNED32
Value range
1 ... (2
32
-1)
Default value
1
The ratio of the values of Sub-indices 08
h
and 09
h
provides the mechanical resolution of the axis in
μm/turn.
Sub-index
0A
h
Brief description
count direction
Unit
Access
rw
PDO mapping
not possible
Data type
UNSIGNED8
Value range
0, 1
Default value
1
The value gives the count direction for current, speed, and position control. A value of 1 means that
the positive count direction has been selected. If a positive setpoint is provided, the motor shaft
rotates in a clockwise direction (looking at the shaft end).
68 CANopen for AX2000/2500
CANopen Drive Profile 07/2007 BECKHOFF
Vista de página 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 136 137

Comentários a estes Manuais

Sem comentários