Vista de página 17
C1300 VME to II/O Interface Unit Beckhoff II/O-System
Page 18 of 44 Version : 2.01 Date : 18.12.95
Funktion 02
h
: Code word request
After each reset the code word is transmitted through the handshake channels by
the C1300 module. This is done without setting the data valid bit. The code word
is used to report that the C1300 module is initialized and ready to work to the
VME system. At any time the code word can be requested by function 02h.
channel length function argument
0
argument
1
argument
2
comment
call
02 02
response
04 02 af fe
codeword correct