Beckhoff AX5000 S-IDN Parameters Manual do Utilizador Página 122

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 190
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 121
SIDNs
S00169Probecontrolparameter
TheparameterspecifieswhichedgesareactivatedbythecommandS00170.
Attributes
Name Value
Format Binary
Datalength 16
Decimalpoint 0
Minvalue
Maxvalue
Defaultvalue
Unit
ChangeableinEtherCATstate PreOp,SafeOp,Op
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision No
Bitpattern:
Bit Meaning
0 Probe1positiveedge
Probe1,positiveedge
0=positiveedgeisnotactive
1=positiveedgeisactive
1 Probe1negativeedge
Probe1negativeedge
0=negativeedgeisnotactive
1=negativeedgeisactive
24 Reserved
5 Modeprobe1
Modeprobe1
0=individualmeasurement
1=continuousmeasurement
67 Reserved
8 Autoactivation
Autoactivation
0=activationwithS00170
1=autoactivationofSafeOpafterOp
9
15
Reserved
Note
IDNsinvolved
S‐0‐0170 [}124]
AX5000IDNDescriptions122 Version3.1