Sx0111Motorcontinuousstallcurrent
TheparametercontainstheRMSvalueofthemotorstandstillcurrent.Itispermissibletoenergizethemotor
continuouslywiththestandstillcurrent,whichgeneratesthestandstilltorque.Thisparametercanbeusedas
areferenceforallmotorsexceptasynchronousmotors,todeterminetorquevalues/forcesandmotor
dependentcurrents.
Attributes
Name Value
Format udec
Datalength 32
Decimalpoint 3
Minvalue
Maxvalue
Defaultvalue
Unit A
ChangeableinEtherCATstate PreOp
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision No
Note
Parametersetswitchoverispossible!
ThisIDNexistsasS00111;S10111;S20111;S30111;S40111;S50111;S60111
andS70111.Exfactory,allvaluesareidentical.