SIDNs
S00207Driveoffdelaytime
Theparametercontainsthedelay“Driveoffdelaytime”.
Attributes
Name Value
Format udec
Datalength 16
Decimalpoint 0
Minvalue 0
Maxvalue 10000
Defaultvalue 150
Unit ms
ChangeableinEtherCATstate PreOp
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision
Themotorbrakemanagementrequiresthistimetoengagethemotorbrakebeforethecontroller(and
thereforeatorquethatmaybepresent)isswitchedoff.
Assoonasbit15ofS00134wasreset,engagingofthemotorholdingbrakeisinitiatedifeither“Maximum
driveoffdelaytime”(S00273)hasrunofforif“n_min”(S00124)hasbeenunderrun.
Assoonas“n_min”(S00124)hasbeenunderrun,“driveoffdelaytime”(S00207)starts.Thecontrol
remainsactiveuntil“thedriveoffdelaytime”haselapsed.
Note
IDNsinvolved
S‐0‐0011 [}12],S‐0‐0134 [}106],S‐0‐0124 [}102],S00273
Alsoseeaboutthis
2 S00273Maximumdriveoffdelaytime[}148]