SIDNs
S00216Switchparameterset(pc)
Theparametercontainstheparametersetswitchovercommand.Thiscommandcanbeusedtoswitch
betweendifferentdatasetsofaparameterset.Thedriveswitchestothedatasetthatisspecifiedwith
S00217.
Attributes
Name Value
Format binary
Datalength 16
Decimalpoint 0
Minvalue
Maxvalue
Defaultvalue
Unit
ChangeableinEtherCATstate Op
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision No
Bitpattern:
Bit Meaning
0 Cancelcmd
Cancelcommand
0=disable
1=enable
1 Setcmd
Setcommand
0=disable
1=enable
2 Reserved
3 Set&enablecommand
Set&enablecommand
0=disable
1=enable
4
15
Reserved