SIDNs
S00405Probe1enable
Thisparameterisusedtoactivateprobeunit1ofthedrive.Thisparametercanbelinkedwitharealtime
controlbit(S00301),sothatactivationispossibleviatheMasterControlWord(S00134).
Attributes
Name Value
Format binary
Datalength 16
Decimalpoint 0
Minvalue
Maxvalue
Defaultvalue
Unit
ChangeableinEtherCATstate PreOp,SafeOp,Op
Cyclictransfer MDT
Deviceparameter No
Relatedtointerfacerevision No
ThedrivechecksthisparameteraslongasS00170isenabled.Tostartanewmeasuringprobecycle,the
valueofthisIDNmustbechangedfrom0to1.
Bitpattern:
Bit Meaning
0 Probe1
Probe1
0=notenabled
1=enabled
1–15 Reserved
Note
IDNsinvolved
S0130,S‐0131 [}105],S‐0‐0170 [}124],S‐0‐0301 [}154],S00303
Note
Additionalfunctionaldescription
AX5000/ProbeUnit
Alsoseeaboutthis
2 S00130Probevalue1positiveedge[}104]
2 S00303Allocationofrealtimecontrolbit2[}155]