Beckhoff AX5000 S-IDN Parameters Manual do Utilizador Página 159

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 190
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 158
SIDNs
S00348Accelerationfeedforwardgain
Theparametercontainstheaccelerationprecontrol.Thisparameterisactiveinmode"Positioncontrollag
less".Itisusedinselectedapplicationstoadditionallyreducefollowingerrorsduringaccelerationand
deceleration.
Attributes
Name Value
Format udec
Datalength 16
Decimalpoint 4
Minvalue 0.0000
Maxvalue 3.2767
Defaultvalue
Unit %/(rad/s²)
ChangeableinEtherCATstate PreOp,SafeOp,Op
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision from0203
Theaccelerationprecontrolgeneratesasetcurrentthatisaddedtothecontrolvalueofthevelocity
controller(precontrol).Thisparametercanbeusedtoadapttheeffectofaccelerationprecontroltothe
application,bylinearlyscalingtheaccelerationcalculatedbydualdifferentiationofthesetposition.The
accelerationprecontrolcanonlybeusedinconnectionwithcubicinterpolation(P00556),becauseaset
accelerationcanonlybecalculatedfromathirdorderinterpolation.
Explanation:
m=torque
α=angularaccelerationofthemotorshaft
J_tot=totalmomentofinertiaactiveatthemotor
K_T=torqueconstantofthemotor
i_q=torquegeneratingmotorcurrent
Calculationexample:
Parametercalculation:
J
tot
=
kgm
2
K
T
=
Nm/
A
rms
P00092=A
rms
100%=Fullcompensation
AX5000IDNDescriptions 159Version3.1
Vista de página 158
1 2 ... 154 155 156 157 158 159 160 161 162 163 164 ... 189 190

Comentários a estes Manuais

Sem comentários